Tennis Programming - Gremlin SPICE reconstruction 0.3.1 * Basis: BNL EH1-900-1-3 A (1958), computing/relay diagram. * See docs/model.json and docs/corrections.json for model boundaries. * No host code changes a ball coordinate, capacitor charge or inductor current. * Raw U2 voltage is zero at the net top; displayed height is V(y)+20 V. * Electronic display sheet EH1-900-2-3 A is NOT represented by this plant. .param RI=1meg CI=1u RFB=10meg CHF=10n RPOT=50k .param NH=20 COURT=75 SERVE=62 G=60 .param A0=10k FP=1 VRAIL=110 ROUT=100 .param RCOIL=10k LCOIL=10 IPICK=50u IHYS=15u .func hi(a) {(1+tanh((a-50)/2))/2} .func positive(a) {(1+tanh(a/.2))/2} .global logic railp railm Vlogic logic 0 100 Vp railp 0 {VRAIL} Vm railm 0 {-VRAIL} Vgravity grav 0 {-G} VknobL knob_l 0 .65 VknobR knob_r 0 .65 VbuttonL button_l_input 0 0 VbuttonR button_r_input 0 0 Vreset reset_input 0 0 RbuttonL button_l_input button_l 1k CbuttonL button_l 0 100n RbuttonR button_r_input button_r 1k CbuttonR button_r 0 100n Rreset reset_input reset 1k Creset reset 0 100n * Finite-gain, dominant-pole amplifier macro-model. Explicit engineering * substitute: the transistor/tube implementation of a Donner 30 is unresolved. .subckt OA s out Berror target 0 V=min(max(-{A0}*V(s),-10000),10000) Rpole target pole {1/(6.283185307179586*FP*1u)} Cpole pole 0 1u Dpositive pole railp DCLAMP Dnegative railm pole DCLAMP Ebuffer buffer 0 pole 0 1 Rout buffer out {ROUT} .ends OA .model DCLAMP D(Is=1e-12 N=1 Rs=1) .model DGE D(Is=1u N=1.5 Rs=20) .subckt CONTACT a b control Bcontact a b I=V(a,b)*(1p+(.02-1p)*(1+tanh((V(control)-55)/.8))/2) .ends CONTACT * Sensitive relay: rectifier, measured-current R-L coil, flyback path, * continuous hysteretic pickup and RC armature surrogate. R/L/thresholds are unmeasured. .subckt RELAY drive contact params: I0=0 Ddrive drive cp DGE Dflyback 0 cp DGE Rcoil cp cn {RCOIL} Lcoil cn sense {LCOIL} ic={I0} Vsense sense 0 0 Bpickup target 0 V=100*(1+tanh((I(Vsense)-{IPICK}+{IHYS}*(V(contact)/50-1))/5u))/2 Rarmature target contact 1k Rrelease contact 0 2k Carmature contact 0 1u .ends RELAY * Bistable contact macro-model. Reset has priority. Charge on Q is retained through * a finite-conductance feedback contact; all memory is capacitor charge. .subckt LATCH set reset q Bkeep logic q I=V(logic,q)*(1p+.001*hi(V(q))) Bset logic q I=V(logic,q)*(1p+.001*hi(V(set))*(1-hi(V(reset)))) Breset q 0 I=V(q)*(1p+.1*hi(V(reset))) Rpull q 0 100k Cmemory q 0 1u .ends LATCH * RY1B..J: four 1 uF controller banks. A capacitor is either charging through * its 50 kOhm path, or connected to the amplifier feedback by two contacts. .subckt BANK sum out ref active p n Vsense cp p 0 Cbank cp n {CI} XfeedbackP p sum active CONTACT XfeedbackN n out active CONTACT Bnot off 0 V=100-V(active) XchargeP p charging off CONTACT Rcharge charging ref {RPOT} XchargeN n 0 off CONTACT .ends BANK * Linked control transfers: explicit adjustable reconstruction calibration. BleftX ref_lx 0 V=100-50*V(knob_l) BleftY ref_ly 0 V=20+85*V(knob_l) BrightX ref_rx 0 V=-(100-50*V(knob_r)) BrightY ref_ry 0 V=20+85*V(knob_r) BselL active_l 0 V=100*hi(V(run_contact))*(1-hi(V(bank))) BselR active_r 0 V=100*hi(V(run_contact))*hi(V(bank)) Xly sy u1 ref_ly active_l lyp lyn BANK Xry sy u1 ref_ry active_r ryp ryn BANK Xlx sx u6 ref_lx active_l lxp lxn BANK Xrx sx u6 ref_rx active_r rxp rxn BANK * U1/U2 and U6/U7: archival 1 megOhm / 1 uF computing chain, with the * 10 megOhm || .01 uF high-frequency feedback branches retained. Rg grav sy {RI} Ryfb sy u1 {RFB} Cyhf sy u1 {CHF} XU1 sy u1 OA Rypos u1 py {RI} Cypos py y {CI} XU2 py y OA Rxfb sx u6 {RFB} Cxhf sx u6 {CHF} XU6 sx u6 OA Rxpos u6 px {RI} Cxpos px x {CI} XU7 px x OA * RY3A/B: 10 uF ground holding network. In sample mode A=0, B=U1 through * 10 kOhm. In bounce mode A=U1, B=sum. Charge redistribution performs bounce. Cground ga gb 10u Rgsample u1 gs 10k BgroundNot ground_not 0 V=100-V(ground_contact) XgroundA0 ga 0 ground_not CONTACT XgroundB0 gb gs ground_not CONTACT XgroundA1 ga u1 ground_contact CONTACT XgroundB1 gb sy ground_contact CONTACT * RY4A/B: 5 uF net holding capacitor, likewise switched with its polarity * reversed into the horizontal feedback path. No restitution multiplier. Cnet na nb 5u BnetNot net_not 0 V=100-V(net_contact) XnetA0 na u6 net_not CONTACT XnetB0 nb 0 net_not CONTACT XnetA1 na sx net_contact CONTACT XnetB1 nb u6 net_contact CONTACT * U3 - unity inverter below the net plane. U4 - adjustable ground detector. Ru3 y s3 1meg Rf3 s3 u3 1meg XU3 s3 u3 OA Vheight h_ref 0 {NH} Ru4a y s4 100k Ru4b h_ref s4 100k Rf4 s4 u4 1meg XU4 s4 u4 OA Xground u4 ground_contact RELAY * U8/U9: symmetric end references. Comparator macro-model polarity is an * explicit working interpretation of the archival diode OR, correction C02. BendR end_r 0 V=min(max(10000*(V(x)-{COURT}),-100),100) BendL end_l 0 V=min(max(10000*(-V(x)-{COURT}),-100),100) DendR end_r end_drive DGE DendL end_l end_drive DGE Rend end_drive 0 1meg Xend end_drive end_contact RELAY * U10/RY5 centre detector. The symmetric RC edge gate corrects the incomplete * one-sided net gating of the surviving drawing (C03); no position is clamped. Bcentre centre_drive 0 V=min(max(10000*V(x),-100),100) Xcentre centre_drive centre_contact RELAY Bedgestep edge_source 0 V=V(centre_contact) Cedge edge_source edge 1n Redge edge 0 10meg Bedgeabs edge_abs 0 V=abs(V(edge)) BnetGate u3 net_drive I=V(u3,net_drive)*(1p+(.02-1p)*(1+tanh((V(edge_abs)-1)/.05))/2) RnetDrive net_drive 0 1meg Xnet net_drive net_contact RELAY * Electrical button conditioning and player interlock. The B sources are * documented logic macro-models (C04), not a transcription of every RY1 wire. BhitL hit_l_drive 0 V=60*hi(10*V(button_l))*hi(V(can_l)) BhitR hit_r_drive 0 V=60*hi(10*V(button_r))*hi(V(can_r)) XhitL hit_l_drive hit_l_contact RELAY XhitR hit_r_drive hit_r_contact RELAY BsetRun set_run 0 V=max(V(hit_l_contact),V(hit_r_contact)) BresetRun reset_run 0 V=max(V(end_contact),V(reset)) XrunLatch set_run reset_run run LATCH BrunDrive run_drive 0 V=.6*V(run) Xrun run_drive run_contact RELAY Xbank hit_r_contact hit_l_contact bank LATCH BsetServer set_server 0 V=100*hi(V(end_contact))*positive(V(end_r)) BresetServer reset_server 0 V=max(V(reset),100*hi(V(end_contact))*positive(V(end_l))) Xserver set_server reset_server server LATCH BresetPermits reset_permits 0 V=max(V(reset_run),100-V(run)) BsetL set_l 0 V=100*hi(V(bank))*(1-hi(V(centre_contact)))*positive(V(y)) BsetR set_r 0 V=100*(1-hi(V(bank)))*hi(V(centre_contact))*positive(V(y)) BresetL reset_l 0 V=max(V(reset_permits),V(hit_l_contact)) BresetR reset_r 0 V=max(V(reset_permits),V(hit_r_contact)) XpermitL set_l reset_l permit_l LATCH XpermitR set_r reset_r permit_r LATCH BcanL can_l 0 V=100*(1-hi(V(run_contact)))*(1-hi(V(server)))+hi(V(run_contact))*V(permit_l) BcanR can_r 0 V=100*(1-hi(V(run_contact)))*hi(V(server))+hi(V(run_contact))*V(permit_r) * RY2 reset/hold contacts. They establish starting voltages by current flow. * X offset source is an explicit serve-position calibration (C05). Bhold hold 0 V=100-V(run_contact) XholdY sy u1 hold CONTACT XholdX sx u6 hold CONTACT XholdPosY py y hold CONTACT Bserve x x_hold V={SERVE}*(2*hi(V(server))-1) XholdPosX px x_hold hold CONTACT * Named telemetry. These voltage probes do not feed the plant. BpreLX pre_lx 0 V=-V(lxp,lxn) BpreLY pre_ly 0 V=-V(lyp,lyn) BpreRX pre_rx 0 V=-V(rxp,rxn) BpreRY pre_ry 0 V=-V(ryp,ryn) .save v(u1) v(y) v(u6) v(x) v(pre_lx) v(pre_ly) v(pre_rx) v(pre_ry) + v(run) v(run_contact) v(can_l) v(can_r) v(server) v(bank) + v(ground_contact) v(net_contact) v(centre_contact) v(end_contact) + i(v.xground.vsense) i(v.xnet.vsense) i(v.xrun.vsense) + i(v.xly.vsense) i(v.xry.vsense) i(v.xlx.vsense) i(v.xrx.vsense) .save v(sy) v(sx) v(py) v(px) v(ga) v(gb) v(na) v(nb) v(edge_source) v(edge) v(button_l) v(button_r) v(reset) v(permit_l) v(permit_r) v(xly.cp) v(lyn) v(xry.cp) v(ryn) v(xlx.cp) v(lxn) v(xrx.cp) v(rxn) v(xu1.pole) v(xu2.pole) v(xu3.pole) v(xu4.pole) v(xu6.pole) v(xu7.pole) v(hit_l_contact) v(hit_r_contact) i(v.xend.vsense) i(v.xcentre.vsense) i(v.xhitl.vsense) i(v.xhitr.vsense) v(railp) v(railm) v(logic) v(grav) .options method=gear maxord=2 reltol=0.0001 abstol=1e-9 vntol=1e-6 chgtol=1p * One electrical solve: computer, loaded line controls, passive supply, * all fifteen PNP selectors and the declared scope terminal macro. .param DISPLAY_EPOCH=0.0000000000000000 Bmains mains 0 V=165.4629867976521*sin(376.9911184307752*(time+DISPLAY_EPOCH)) Xinstrument mains net_v net_h court_v court_h dpp12 dpp6 dmm6 dmm22 TFT_INSTRUMENT Xdisplay y x net_v net_h court_v court_h screen_y screen_x phase_a phase_b phase_c dpp12 dpp6 dmm6 dmm22 TFT_DISPLAY BETA=75 Xscope screen_x screen_y plate_x plate_y beam_i TFT_SCOPE .ic v(xdisplay.base_l)=.01 v(xdisplay.base_r)=.02 v(xdisplay.ff_bl)=.01 v(xdisplay.ff_br)=.02 .temp 25 * Keep capacitor/selector states and probes, rather than all algebraic branch * currents. The circuit solve is identical; only stored plot size changes. .save v(xdisplay.base_l) v(xdisplay.base_r) v(xdisplay.emit_l) v(xdisplay.emit_r) v(xdisplay.ff_bl) v(xdisplay.ff_br) v(xdisplay.ff_el) v(xdisplay.ff_er) v(xdisplay.ff_l) v(xdisplay.ff_r) v(xdisplay.osc_l) v(xdisplay.osc_r) v(xdisplay.pulse_tap) v(xdisplay.trigger) v(xdisplay.xkeys.ah_b) v(xdisplay.xkeys.ah_c) v(xdisplay.xkeys.av_b) v(xdisplay.xkeys.av_c) v(xdisplay.xkeys.bh_b) v(xdisplay.xkeys.bh_c) v(xdisplay.xkeys.bv_b) v(xdisplay.xkeys.bv_c) v(xdisplay.xkeys.ch_b) v(xdisplay.xkeys.ch_c) v(xdisplay.xkeys.cv_b) v(xdisplay.xkeys.cv_c) v(xscope.pole_x) v(xscope.pole_y) v(plate_x) v(plate_y) v(beam_i) v(screen_x) v(screen_y) v(phase_a) v(phase_b) v(phase_c) v(net_v) v(court_h) .save all * Electronic Switch for Tennis Programming, BNL EH1-900-2-3 A, 1959-11-18. * Transcription of the timing/selector network; external supply rails and * six analogue computer outputs are ports. Transformer/bridge/CRT omitted. * Q identifiers are ours: the archival sheet gives no device designators. * * DEVICE MODEL STATUS: preliminary Ge PNP Gummel-Poon surrogate. RCA SC-11 * (1964), printed p.131, gives typical small-signal hfe=75 at Ic=.6mA, * Vce=-9V, and identifies 2N140 as Ge PNP. It is NOT a fitted switching model. * IS/BR/VAF/CJ/TF/TR and the 1N100 surrogate below are engineering assumptions. * Maximum ratings are not avalanche thresholds and are not used as such. .subckt TFT_DISPLAY av ah bv bh cv ch scope_v scope_h phase_a phase_b phase_c pp12 pp6 mm6 mm22 params: BETA=75 ISGE=1u REVERSE=5 CTIME=.5u .model GE140 PNP(IS={ISGE} BF={BETA} BR={REVERSE} VAF=45 + RB=50 RC=5 RE=2 CJE=100p CJC=10p TF=20n TR=100n EG=.67 XTI=3 TNOM=25) .model GE100 D(IS=1u N=1.3 RS=20 CJO=2p EG=.67 XTI=3 TNOM=25) * Astable: 20k base returns, .5uF cross-coupling. The right 2k load is * drawn as two 1k resistors, with the pulse pickoff at their midpoint. Racl osc_l 0 2k Rabl base_l 0 20k Rabr base_r 0 20k Racr1 pulse_tap 0 1k Racr2 osc_r pulse_tap 1k Cacl osc_l base_r {CTIME} Cacr osc_r base_l {CTIME} Qal osc_l base_l emit_l GE140 Qar osc_r base_r emit_r GE140 Rael emit_l pp6 510 Raer emit_r pp6 510 * Emitter-current inverters. The right astable drives BOTH B and C, * suppressing those selectors while A is selected. Qda phase_a emit_l pp6 GE140 Qdb phase_b emit_r pp6 GE140 Qdc phase_c emit_r pp6 GE140 * Positive differentiated edge toggles the cross-coupled bistable. Ctrigger pulse_tap trigger 1n Rtrigger trigger 0 5.1k DtriggerL trigger ff_l GE100 DtriggerR trigger ff_r GE100 Rfcl ff_l 0 2k Rfcr ff_r 0 2k Rfbl ff_bl pp12 30k Rfbr ff_br pp12 30k RfcrossL ff_l ff_br 10k RfcrossR ff_r ff_bl 10k CfcrossL ff_l ff_br 1n CfcrossR ff_r ff_bl 1n Qfl ff_l ff_bl ff_el GE140 Qfr ff_r ff_br ff_er GE140 Rfel ff_el pp6 510 Rfer ff_er pp6 510 Qdfb phase_b ff_el pp6 GE140 Qdfc phase_c ff_er pp6 GE140 * Three level-shifted selector drives. The left diode symbol faces left * on the sheet but has the SAME electrical polarity as the other two: * anode at -6V, cathode at the phase collector. Rpa phase_a mm22 5.1k Rpb phase_b mm22 5.1k Rpc phase_c mm22 5.1k Dpa mm6 phase_a GE100 Dpb mm6 phase_b GE100 Dpc mm6 phase_c GE100 RpullA phase_a pp12 51k RpullB phase_b pp12 51k RpullC phase_c pp12 51k Xkeys av ah bv bh cv ch scope_v scope_h phase_a phase_b phase_c TFT_KEYS BETA={BETA} ISGE={ISGE} REVERSE={REVERSE} .ends TFT_DISPLAY * Separate key bank permits DC transfer/leakage tests of the SAME devices. .subckt TFT_KEYS av ah bv bh cv ch scope_v scope_h phase_a phase_b phase_c params: BETA=75 ISGE=1u REVERSE=5 .model GE140 PNP(IS={ISGE} BF={BETA} BR={REVERSE} VAF=45 + RB=50 RC=5 RE=2 CJE=100p CJC=10p TF=20n TR=100n EG=.67 XTI=3 TNOM=25) * Six PNP analogue keys, 51k/1k input dividers and common emitter outputs. * No ideal switches, behavioural oscillators or externally scheduled gates. Rav av av_c 51k Rav0 av_c 0 1k Ravb phase_a av_b 51k Qav av_c av_b scope_v GE140 Rah ah ah_c 51k Rah0 ah_c 0 1k Rahb phase_a ah_b 51k Qah ah_c ah_b scope_h GE140 Rbv bv bv_c 51k Rbv0 bv_c 0 1k Rbvb phase_b bv_b 51k Qbv bv_c bv_b scope_v GE140 Rbh bh bh_c 51k Rbh0 bh_c 0 1k Rbhb phase_b bh_b 51k Qbh bh_c bh_b scope_h GE140 Rcv cv cv_c 51k Rcv0 cv_c 0 1k Rcvb phase_c cv_b 51k Qcv cv_c cv_b scope_v GE140 Rch ch ch_c 51k Rch0 ch_c 0 1k Rchb phase_c ch_b 51k Qch ch_c ch_b scope_h GE140 .ends TFT_KEYS * Oscilloscope terminal/deflection MACROMODEL, not a tube-by-tube DuMont. * DuMont Oscillographer 14(1), 1953, pp.13,19-20: X input 2.2Mohm||50pF, * Y input 2Mohm||50pF; 5ADP deflection factors at Eb2=1.6kV: * X 48V/in, Y 36.8V/in. These are nominal instrument-family values. * Gain, position, pole implementation, clamp and grid setting are OUR calibration. * Two equal 300kHz RC poles give |H(100kHz)|=.9, |H(300kHz)|=.5. * Tube/gun supplies are ideal. No power transformer, heater or tube ageing model. .subckt TFT_SCOPE in_x in_y plate_x plate_y beam_i RinputX in_x 0 2.2meg RinputY in_y 0 2meg CinputX in_x 0 50p CinputY in_y 0 50p BtargetX target_x 0 V=min(max(54*(V(in_x)+.11665),-110),110) BtargetY target_y 0 V=min(max(44*(V(in_y)+.11665)-30,-110),110) RpoleX1 target_x pole_x 1k CpoleX1 pole_x 0 530.5164769729845p EbufferX buffer_x 0 pole_x 0 1 RpoleX2 buffer_x plate_x 1k CpoleX2 plate_x 0 530.5164769729845p RpoleY1 target_y pole_y 1k CpoleY1 pole_y 0 530.5164769729845p EbufferY buffer_y 0 pole_y 0 1 RpoleY2 buffer_y plate_y 1k CpoleY2 plate_y 0 530.5164769729845p * Grid-current law is a declared 3/2-power gun surrogate, not a fitted 5ADP1. Vgrid grid 0 -15 Vaccel anode 0 1600 Bgun anode 0 I=25u*(max(0,1+V(grid)/48)/.6875)^1.5 * Current is exposed as a voltage-valued telemetry port (1 V = 1 A). Bcurrent beam_i 0 V=-I(Vaccel) .ends TFT_SCOPE * BNL EH1-900-2-3 A: passive supply, transcription research. * 117/36 interpreted as RMS, 60Hz chosen US mains. Core effects omitted. * RW, ESR and semiconductor parameters are declared uncertain assumptions. * Ideal transformer has reciprocal primary current: energy conservation. .subckt TFT_SUPPLY primary pp12 pp6 mm6 mm22 params: RATIO=.3076923076923077 RW=2 ESR=.5 CF=50u DRS=10 DIS=1u Etransform secdrive secreturn primary 0 {RATIO} Fprimary primary 0 Etransform {-RATIO} Rwinding secdrive sec_a {RW} Rreference secreturn 0 1g .model RECT_GE D(IS={DIS} N=1.3 RS={DRS} CJO=2p EG=.67 XTI=3 TNOM=25) D1 sec_a rect_p RECT_GE D2 secreturn rect_p RECT_GE D3 mm22 sec_a RECT_GE D4 mm22 secreturn RECT_GE Rseries rect_p pp12 10 Rdivider1 pp12 pp6 120 Rdivider2 pp6 0 180 Rdivider3 0 mm6 120 Rdivider4 mm6 mm22 390 Resrp12 pp12 cp12 {ESR} Cfp12 cp12 0 {CF} Resrp6 pp6 cp6 {ESR} Cfp6 cp6 0 {CF} Resrm6 mm6 cm6 {ESR} Cfm6 0 cm6 {CF} Resrm22 mm22 cm22 {ESR} Cfm22 0 cm22 {CF} .ends TFT_SUPPLY * Operating calibration preserves the calculator's raw ground=-20V/net-top=0V. * NET_AC=50Vrms comes from the annotated input. Its DC reference and both * potentiometer positions are declared reconstruction settings, not recovered. * Court secondary131.5Vrms is chosen, not specified in the surviving drawing. .subckt TFT_INSTRUMENT mains net_v net_h court_v court_h pp12 pp6 mm6 mm22 Xsupply mains pp12 pp6 mm6 mm22 TFT_SUPPLY VnetRef net_ref 0 -11.5 Enet net_drive net_ref mains 0 {50/117} Fnet mains 0 Enet {-50/117} RnetTop net_drive net_v 41650 RnetBottom net_v net_ref 8350 VnetH net_h 0 0 VcourtV court_v 0 -20 Ecourt court_drive 0 mains 0 {131.5/117} Fcourt mains 0 Ecourt {-131.5/117} RcourtTop court_drive court_h 25k RcourtBottom court_h 0 25k .ends TFT_INSTRUMENT .end