* Oscilloscope terminal/deflection MACROMODEL, not a tube-by-tube DuMont. * DuMont Oscillographer 14(1), 1953, pp.13,19-20: X input 2.2Mohm||50pF, * Y input 2Mohm||50pF; 5ADP deflection factors at Eb2=1.6kV: * X 48V/in, Y 36.8V/in. These are nominal instrument-family values. * Gain, position, pole implementation, clamp and grid setting are OUR calibration. * Two equal 300kHz RC poles give |H(100kHz)|=.9, |H(300kHz)|=.5. * Tube/gun supplies are ideal. No power transformer, heater or tube ageing model. .subckt TFT_SCOPE in_x in_y plate_x plate_y beam_i RinputX in_x 0 2.2meg RinputY in_y 0 2meg CinputX in_x 0 50p CinputY in_y 0 50p BtargetX target_x 0 V=min(max(54*(V(in_x)+.11665),-110),110) BtargetY target_y 0 V=min(max(44*(V(in_y)+.11665)-30,-110),110) RpoleX1 target_x pole_x 1k CpoleX1 pole_x 0 530.5164769729845p EbufferX buffer_x 0 pole_x 0 1 RpoleX2 buffer_x plate_x 1k CpoleX2 plate_x 0 530.5164769729845p RpoleY1 target_y pole_y 1k CpoleY1 pole_y 0 530.5164769729845p EbufferY buffer_y 0 pole_y 0 1 RpoleY2 buffer_y plate_y 1k CpoleY2 plate_y 0 530.5164769729845p * Grid-current law is a declared 3/2-power gun surrogate, not a fitted 5ADP1. Vgrid grid 0 -15 Vaccel anode 0 1600 Bgun anode 0 I=25u*(max(0,1+V(grid)/48)/.6875)^1.5 * Current is exposed as a voltage-valued telemetry port (1 V = 1 A). Bcurrent beam_i 0 V=-I(Vaccel) .ends TFT_SCOPE